Allows to increase the value of the selected parameter. WARNING! It has been designed with compliance to the European Directives. Fsc allows the scaling of the analog input to set the maximum displayed/measured value. When the upper display is showing a group and the lower display is blank, this key allows to enter in the selected group. (63% response when the input changes from 10% 90%). We assume no liability for safety, or responsibility for the, product's quality, performance or functionality should users fail to. voltage contact between terminals 4 and 16; - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. It has been de-, signed with compliance to the European Directives. Are the TC10s wiring terminals screw terminals? If this instrument is used in a manner not specified in this manual. Set detailed parameter out group o1.F (output 1 function) = r.inP. can be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Yokogawa Europe BV (Address: Euroweg 2 , 3825 HD Amersfoort, The Netherlands) is the Authorised Representative of. Download this manual TEMPERATURE CONTROLLER Model: TC10 - Quick Guide . The short depth of the controller helps save instrument panel space. ]inP Group - Main and auxiliary input conguration. The output relay is always de-energized (opened) at poweron,even if PV does not exceed SP(A). If applicable, a timer count control monitors the amount of time outside the setpoint and registers the maximum temperature reached. user must refer to the Engineering manual for special instructions. We call this set conguration parameter set (or conguration parameters). The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. ), Panel cutout: 45[-0, +0.6] x 45[-0, +0.6] mm (1.78[- 0.000, +0.023] x 1.78[- 0.000, +0.023] in.). Do not short-circuit the terminals of the SSR output. values and the controller output instantaneous value. Note: For TC wiring use proper compensating cable preferable shielded. Please, provide a T type 1A, 250 V fuse externally. Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. Select a mounting location having the following characteristics: 2. The. displayed value becomes 999.9C or 999.9F. The 3-year warranty extends 36 months after shipment from our factory. The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the. 2 Cold junction accuracy:0.05C/C after a warm-up of 20 minutes. A double or reinforced isolation between logic inputs and power line must be assured by the external elements. Is there a controller to which I can connect a 2-wire Pt1000 sensor? connected between sensor and input terminals may cause errors in measurement due to excessive and/or not balanced line resistance or possible leakage currents. SSc allows the scaling of the analog input to set the minimum displayed/measured value. countries or regions where wiring will be installed. The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. Digital indicating controllers (82 pages), Digital indicating controller (236 pages), Digital indicating controllers (13 pages), Digital indicating controller
of use, service life and misuse are not covered by this warranty. Yes, if the input type is voltage or current. Main Features Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals) 3 Dynamic Colors Led Display The access to the conguration parameters is protected by a password. (100 to 240 VAC), Insulation voltage: 2300 V rms according to EN 61010-1, Front protection: IP 65 (when the optional panel gasket is mounted), Accessories: Mounting bracket, Quick Guide, Operative Modes: Auto / Manual / Stand-by (force control output to zero), Serial Communication (optional): RS-485 MODBUS, PID control with single or double action with overshoot control (Fuzzy overshoot control), ON/OFF, ON/OFF Neutral Zone, Auto-tuning, and Self-tuning. - For control relay output, alarm relay output, and power terminal, -N o C o o o D o F Temperature Controller, The TC10-N can be easily configured by the "Code Configuration" method for the most common requirements, just entering two 4-digit. - Install the power cable keeping a distance of more than 1 cm from, - The power cable is required to meet the IEC standards concerned or the. - As a safety measure, always install a circuit breaker (an IEC 60947, compatible product, 5 A, 100 V or 220 V AC) in an easily accessible, location near the instrument. The short depth of the controller helps save instrument panel space. 3. Brand: digitalview. V output: 0/2 10 V, galvanically isolated, RL min. This manual is intended for the following personnel: - Engineers responsible for installation, wiring, and maintenance of, - Personnel responsible for normal daily operation of the, Calls attention to actions or conditions that could cause serious or, fatal injury to the user or damage to the instrument, and indicates, precautions that should be taken to prevent such occurrences. There is minimum vibrations and no impact; 4. 4 2.4 SERIAL INTERFACE. I want to use the detailed parameter setting method of TC10, but what number is the password? : control, alarms, output functions). View online Manual for YOKOGAWA TC 10-L Controller or simply click Download button to examine the YOKOGAWA TC 10-L guidelines offline on your desktop or laptop computer. Looking for more information on our people, technology and solutions? and workmanship for 18 months from the date of manufacturing. rear housing, exposed terminals and wiring on the back. There is no parameter for specifying the output direction. and General Specification: GS 05C01E81-01EN. The cable length must not exceed 1.5 km at 9600 baud. 2. On the TC10, I want the difference lower limit alarm to be ON 5C below the setpoint value. and access the next parameter within the same group. I want to use the detailed parameter setting method of TC10, but what number is the password? In the following pages we will describe all the parameters of the instrument. The shallow depth of the controller helps save to space. Copyright 1994-2023 Yokogawa Corporation of America. Pt 1000 input circuit: Current injection (15,5 A). 6. Code: IM 05C01E81-02EN. connected between sensor and input terminals may cause errors in measurement due to excessive and/or not balanced line resistance or possible leakage currents. All information about the controller use can be found in the Engineering Manual: IM 05C01E81-12EN and the Communication Manual: IM 05C01E81-13EN and General Specification: GS 05C01E81-11EN. Product Manual Product Specs Overview Description Documents In Stock All information about. At this point you can set the operator. Note: This filter will affect the measured value but also the control action the analogue retransmission and the alarms, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. The UT75A also support open networks such as Ethernet communication. Fr 8am to 5pm ET, The Yokogawa TC10-L Temperature Controller is recommended replacement. NOTE: This parameter will be shown only when a TC or RTD input has been selected. Looking for more information on our people, technology and solutions? 1, This instrument is intended for permanent installation, for, indoor use only, in an electrical panel which encloses the. Controller YOKOGAWA TC 10-L Engineering Manual 20 pages. The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. For measurements performed in the building, For measurements performed at the source of, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. The shallow depth of the controller helps to save instrument panel space. We assume no liability for safety, or responsibility for, the product's quality, performance or functionality should users. The EU Declaration of Conformity and the manual of the controller. 3 2.3 OUTPUTS Safety notes: - To avoid electrical shocks, connect power line at last. Does the TC10 come with a terminal cover? The EU Declaration of Conformity and the manual of the controller. Do I need a minus sign ( - ) on the alarm setting value? : input type, Control strategy, alarms, etc.). requirements of the area in which the instrument is being installed. The /GK suffix code means it comes with a panel gasket. Select a mounting location having the following characteristics: 2. To protect the AL2 and AL3 thresholds against, undesired changes, they are available only at "Parameters, list" level (password: 20). Note: For TC wiring use proper compensating cable preferable shielded. OUTLINE DIMENSIONS (mm) 1.1 INSTRUMENT DIMENSIONS 1.2 PANEL CUT-OUT 65 mm min. (limit control type) (150 pages), Programmable /indicating controller (96 pages), Digital indicating controller (108 pages), Digital indicating controllers (109 pages), Manual will be automatically added to "My Manuals", Controller YOKOGAWA TC 10-L Engineering Manual, Controller YOKOGAWA UT350 Instruction Manual, Controller YOKOGAWA UTAdvanced UT35A Technical Information, Controller YOKOGAWA Fluidcom S2 User Manual, Controller YOKOGAWA UT35A Operation Manual, Controller YOKOGAWA UT32A-R Operation Manual, Controller YOKOGAWA YS1000 Series User Manual, Controller Yokogawa FA-M3 System Upgrade Manual, Controller YOKOGAWA UT750 Instruction Manual. Use of the, instrument in a manner not prescribed herein may compromise, the product's functions and the protection features inherent in, the device. Can I output in the 100% direction (20 mA or more) upon burnout? [4]FSc - Full scale read-out for linear input. This is a list of recorder and controller products that support the New Legislative Framework (NLF.). 0 mA = 0 mBar and 20 mA = -1000 mBar (vacuum). These two keys allow to return to the previous. Cold junction accuracy: 0.04C/C after a warm-up of 20 minutes. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O, Upload manuals that we do not have and get. The TC10 supports easy configuration with codes for quick start-up. values and the controller output instantaneous value. use only, in an electrical panel which encloses the rear housing. At power ON the instrument can operate in two different mode according to the value assigned to [34] r.md parameter [34] r.md equal to 0, (Limit output is de-energized at power on in any cases.). Products and components that are subject to wear due to conditions. Can I hide the SP display? The UT35A/UT32A also support open networks such as Ethernet communication. For SSR, mA and V outputs if the line length is longer than 30 m use a shielded wire. What settings should I use to output PV transmission from ananalog output terminal on TC10? - Modification of the product is strictly prohibited. The shallow depth of the controller helps to save instrument panel space. It has been designed with compliance to the European Directives. The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. There are no water or other fluids (i.e. Can I use the DI function to switch between auto/manual and between run stop/start? a TC J input is programmed). - Installation of protection and/or safety circuits with respect to a, lightning protector; protective equipment for the system controlled, by the product and the product itself; foolproof or failsafe design, of a process or line using the system controlled by the product or, the product itself; and/or the design and installation of other, protective and safety circuits are to be appropriately implemented, - This product is not designed or manufactured to be used in critical, applications that directly affect or threaten human lives. Note: The complete list of the default parameters is available in Appendix A. Copyright 1994-2023 Yokogawa Electric Corporation. TC10-L is capable of a retransmission . It also includes a ladder sequence function. It has been de- signed with compliance to the European Directives. Other part numbers are available to order but are not currently in stock. When the upper display is showing a parameter and, Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. connected to the low-voltage installation. When a shielded cable is used, it should be connected at one point only. For different configurations, see, Wattmeter (instantaneous power expressed in kW) (note 1), Wattmeter (Power consuption expressed in kWh/h) (note 2), Absolute worked time (expressed in days) (note 3), Absolute worked time (expressed in hours) (note 3), Notes: 1. Do not run logic input wiring together with power cables; The instrument needs 150 ms to recognize a contact status variation; Logic inputs are NOT isolated by the measuring input. The 3-year warranty extends 36 months after shipment from our factory. Model: TC10 - Quick Guide . The following general safety precautions must be observed during. Note: Before starting the configuration code setting, please define and write down Cod1 and Cod2 as needed: Linear 0 to 20 mA (this selection forces Out 4 = TX), Linear 4 to 20 mA (this selection forces Out 4 = TX), Note: As default, when the alarms are active, only AL1 threshold, is available at "Operator Command" level to perform non, critical tasks. 4. period. Clamp meters use wide jaws that clamp around the outside of an electrical conductor to provide non-contact current measurements. The instrument will show a measured value up to 5% higher than [4] FSc value and then it will show, Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. and General Specification: GS 05C01E81-11EN. The short depth of the controller helps save instrument panel space. A reinforced isolation must be assured by the external solid state relays. The factory default password for conguration parameters is equal to 30. Line resistance: Automatic compensation up to 20W/wire with maximum error 0.1% of the input span. observe these instructions when operating the product. Safety, Protection and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. 1. Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), IP65 front panel (when the optional panel gasket is mounted)(optional), Power consumption: 4.5 VA max. Burn out: full scale Calibration:According to EN 60584-1. The shallow depth of the controller helps to save instrument panel space. With the /GK suffix, the TC10 supports the IP65. Copyright 1994-2023 Yokogawa Electric Corporation, {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Special Solutions of OpreX Transformation, Visual MESA Supply Chain Scheduling (VM-SCS), Visual MESA Production Accounting (VM-PA), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), Digital Plant Operation Intelligence (DPI) Quality Stabilization System, OpreX Data Model Broker / Design Data Validation, OpreX Customer Service Management Software, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Single-Cell Analysis Solution Single Cellome, Distributed Temperature Sensor - Fire Detection/Fire Prevention -, Industry and Interface Libraries (Applications and Interfaces), Advanced Control Bioreactor System BR1000, ALH for FlowCam: Automated Liquid Handling, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, TC10-L Temperature Controller Limit Control Type Engineering Manual, TC10-L Temperature Controller Limit Control Type Serial communicaiton protocol, TC10-L Temperature Controller (Limit Control Type), Model TC10-L Temperature Controller (Limit Control Type), Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), Limit control function (High limit / Low limit), IP65 front panel (when the optional panel gasket is mounted)(optional). Push button for more than 3 seconds, the instrument will come back to the standard display. Select a mounting location having the following characteristics: 2.There is minimum vibrations and no impact; 4.There are no water or other uids (i.e. user must refer to the Engineering manual for special instructions. The TC10 communication setting criteria are as follows. Moreover, provide indication that the. The shallow depth of the controller helps to save instrument panel space. Clamp meters can perform analyses in the field on live conductors without interrupting the circuit. Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. Every change of the SEnS parameter will produces a change of the related parameter and in particular: [11] Ao1L and [12] Ao1H (when the analog retransmission is present) will be forced to the Ex.Range limits. and workmanship for 18 months from the date of manufacturing. condensation); 5. about the controller use can be found in the Engineering Manual: IM 05C01E81-12EN and the Communication Manual: IM 05C01E81-13EN. IM 05C01E81-01EN 1 Edition Oct. 2014 st Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan internet site: www.yokogawa.com/ns Declaration of conformity and Manual retrieval TC10 is a panel mounting, Class II instrument. Can I hide the SP display? countries or regions where wiring will be installed. A long press allows you to close the conguration parameter procedure (the instrument will come back to the standard display). (100 to 240 VAC), Insulation voltage: 3000 V AC for 1 minute between primary and secondary terminals, Front protection: IP 65 (when the optional panel gasket is mounted), Accessories: Mounting bracket, Quick Guide, Serial Communication (optional): RS-485 MODBUS. {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Special Solutions of OpreX Transformation, Visual MESA Supply Chain Scheduling (VM-SCS), Visual MESA Production Accounting (VM-PA), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), Digital Plant Operation Intelligence (DPI) Quality Stabilization System, OpreX Data Model Broker / Design Data Validation, OpreX Customer Service Management Software, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Single-Cell Analysis Solution Single Cellome, Distributed Temperature Sensor - Fire Detection/Fire Prevention -, Industry and Interface Libraries (Applications and Interfaces), Advanced Control Bioreactor System BR1000, ALH for FlowCam: Automated Liquid Handling, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, Support InformationNew Legislative Framework (NLF) Conforming Products, Temperature Control for Seal-heating Parts in Wrapping Machinery. the protection provided by this instrument may be impaired. Only wire the other instruments SG terminal. 5, the lower display is showing its value, this key allows, to store the selected value for the current parameter. The instrument have one complete parameter set. For SSR, mA and V outputs if the line length is longer than 30 m use a shielded wire. Every group denes all parameters related with a specic function (e.g. that no power is being supplied to a cable to be connected. - Do not short-circuit the terminals of the SSR output.
Scorpio Weekly Career Horoscope 2020,
Articles Y